Data Cables and Interfaces

Showing all 37 results

Anti-islanding box 63A single and three phase

The anti-islanding box is a complete pre-wired and easy to install anti-islanding device consisting of a Ziehl anti-islanding relay (model UFR1001E or model SPI1021), the required circuit breakers and a 63A contactor.

$1,858.08

Anti-islanding relay UFR1001E

The grid- and plant protection device UFR1001E monitors voltage and frequency in plants for own generation of electricity. It complies with the requirements of VDE-AR-N 4105:2018-11, VDE-AR-N 4110:2018-11, G98, G99, ÖVE/ÖNORM E 8001-4- 712:2009 and other standards for generators connected to the public grid. The UFR1001E is a dual-channel device and thus one-fault-proof.

$1,314.31

CANUSB interface

The CANUSB interface allows you to connect a VE.Can product to your computer. One CANUSB package contains the CANUSB adapter, two VE.Can RJ45 terminators and a manual. Drivers and software must be downloaded from the website.

$815.15

VE.Direct to VE.Can interface

The VE.Direct to VE.CAN interface cable can be used to make BMV-700 information available on a VE.Can network. To install the cable, simply connect it between the VE.Bus device and the solar charger(s). Separately powering the VE.Can network is not necessary, since it is powered by the solar charger(s). Same for the VE.Bus network, it will be powered by the VE.Bus device.

$456.39

Energy Meters ET112, ET340 & EM24

The ET112 and the ET340 Energy Meters are typically used in an Energy Storage System and the EM24 is for 3 phase monitoring only. ET112 is for single phase with max. 100A, ET340 is for three phase max. 65A per phase and EM24 is for three phase max 65 A per phase Energy Meters.

It is used to measure the power and energy of the whole application at the distribution box or to measure the output of a PV Inverter, to display the data on the Color Control GX and the VRM Portal.

$137.56$444.30

VE.Direct to NMEA2000 interface

This NMEA2000 drop cable makes the BMV-700 information available to an NMEA2000 networks. Battery information such as voltage, current and state of charge can be displayed on common purpose displays from other manufacturers which accept the NMEA2000 data being sent.

NMEA 2000 requires a single backbone where products must connect to with drop cables. The BMV drop cable is equipped with a Micro-C (M12) male connector for this purpose, intended to be connected to a corresponding T-connector in the backbone.

$342.97

VE.Bus to NMEA2000 interface

It transmits monitoring information, AC voltages and currents, DC voltages and currents and the state. Other NMEA2000 devices can also send commands to the VE.Bus product to turn it on or off, or change the input current limit.

NMEA 2000 requires a single backbone where products must connect to with drop cables. The VE.Net to NMEA 2000 drop cable is equipped with a Micro-C (M12) male connector for this purpose, intended to be connected to a corresponding T-connector in the backbone

$342.97

VE.Bus to VE.Can interface

This interface is used in Hub-1 systems with grid-feedback enabled. It interfaces between the VE.Bus system and one or more MPPT solar chargers with a VE.Can connection: the MPPT 150/70 and/or MPPT 150/85. Many of our customers integrate our products into their own systems, using data communication protocols. There are several options to establish data communication.

$313.22

Zigbee to RS485 converter

This low power Zigbee standard allows for wireless data transmission over short distances. This devices are standard DC5-12V power and come with a small external antenna.

$180.32

Zigbee to USB converter

This low power Zigbee standard allows for wireless data transmission over short distances. The devices are USB 5V power and come with a small external antenna

$156.15

VE.Can to NMEA2000 Micro-C male

This NMEA2000 cable is used to connect a Victron product with a VE.Can port to a NMEA2000 network. NMEA 2000 requires a single backbone where products must connect to with drop cables. The BMV drop cable is equipped with a Micro-C (M12) male connector for this purpose, intended to be connected to a corresponding T-connector in the backbone.

$156.15

VE.Bus Smart dongle

The VE.Bus Smart dongle is a Bluetooth Smart enabled VE.Bus interface, with battery temperature-and-voltage sensing. It communicates system information straight to your smart phone – using the free-to-use VictronConnect app.

When used with Multi- inverter/chargers the dongle provides on-battery temperature and voltage sensing capabilities – allowing compensation for possible cable losses which can occur during charging and discharging.

$148.72

Interface MK2-USB

Phoenix chargers are ready to communicate with a computer through its RS-485 data port. All you need to link to your PC in order to be able to set and read out all parameters.

$123.60

Interface MK3-USB

The MK3-USB allows you to connect your computer with all inverters and inverter/chargers that have a VE.Bus communication port.

$116.17

VE.Direct to Global Remote interface

The VE.Direct to Global remote interface allows you to connect BMV 700 series products to a Global Remote. It is used to make BMV-700 information available on the Global remote.

$109.82

Interface MK2.2b (VE.Bus to RS232)

Phoenix converters can communicate with a computer through their RS 232 communications port. All you need to connect your PC, in order to set up and read all the parameters, is the data connection kit as shown.

$91.09

VE.Direct Bluetooth Smart dongle

With the VE.Direct to Bluetooth Smart dongle you can get live status info, see historical values as well as configure Victron products. The dongle works together with the VictronConnect App, available for both Android and iOS devices. The dongle can be connected to almost all Victron products that have a built-in VE.Direct port.

$78.07

AC Current sensor

The AC Current sensor is a simple external current sensor used to measure AC Current, Power (VA) and calculate energy of a PV Inverter connected to the AC input or output of a Multi or Quattro. Use the AC Current sensor to measure and visualise the solar production of a PV Inverter. The measurements will be visible on the GX device and on the VRM Portal.

$78.07

Cables with M8 circular connector

Cables with M8 circular connector is used for 12.8V Li-Ion batteries. It is available in different sizes i.e. Male to Female 3 pole 1 m (bag of 2), Male to Female 3 pole 2 m (bag of 2), Male to Female 3 pole 3 m (bag of 2), Male to Female 3 pole 5 m (bag of 2). You can order any of them according to your choice.

$54.85$70.64

RJ12 UTP Cable

Victron Energy RJ12 UTP Cable is available with different sizes including 0.3 m, 0.9 m, 1.8, 3 m, 5 m, 10 m, 15 m, and 30 m. For use with ESP System, BMV-600 and BMV-700 Energy meters, this is a replacement for the cable that joins the shunt and the meter.

$12.06$66.00

VE.Bus to BMS 12-200 alternator control cable

With this cable the charge control feature of the BMS 12/200 can be used together with the VE.Bus BMS. The BMS 12/200 will limit charge current by the alternator to a safe value, and and stop the charge process in case of an alarm (the Li-ion battery is communicates with the VE.Bus BMS and the VE.Bus BMS transmits to the BMS 12/200)

$61.34

RJ45 UTP Cable

A cable to connect VE.Can, VE.Bus, VE.Net, and VE9bitRS485 devices. Victron Energy RJ45 UTP Cable is available in different sizes including 0.3 m, 0.9 m, 1.8, 3 m, 5 m, 10 m, 15 m, 20 m, and 30 m.

$12.06$57.62

Skylla-i remote on-off cable

This cable is intended for on/off control of the Skylla-i when the source signal is high when the Skylla-i must be on, and low or free floating when Skylla-i must be off. Use this cable to connect a Skylla-i to a VE.Bus BMS. The VE.Bus BMS will then disable the Skylla-i charger when the batteries are fully charged.

  • Maximum input voltage: 70 V
  • Minimum input voltage needed for switch on: approximately 6 V
  • Switch off level: input voltage must be less than 1 V or must be free floating
$56.68

RS485 to USB interface

The Victron Energy RS485 to USB Interface allows you to connect the energy meter ET112 or ET340 to the Color Control GX. It is used for direct connection. There are two options available regarding the length of cable and you can choose any of them according to your requirements. It is available in 1.8m cable length and 5.0m cable length.

$43.70$50.19

Temperature sensor VENUS/PMP/Quattro

Victron Energy temperature sensor for Venux GX, Phoenix MultiPlus and Quattro. It helps you in monitoring the temperature of your Victron Energy products. Quattro and Multiplus units are supplied with this temperature sensor. For Venux GX or if any the temperature sensor of your Phoenix MultiPlus and Quattro is damaged, you can order it now.

$50.19

RS232 to USB converter

The Victron Energy RS232 to USB Interface allows you to connect the RS232 port of your Victron unit to a USB port of your computer for configuration and monitoring. All you need to do is connect RS232 connector to your Victron unit and USB connector to your computer and you are ready to configure and monitor the unit.

$48.33

VE.Direct to USB interface

The VE.Direct to USB interface connects products with a VE.Direct connection to devices with a USB port, for example a computer. With this cable it is also possible to connect more than two VE.Direct products to a single CCGX.

$46.47

VE.Direct to RS232 interface

The VE.Direct to RS232 interface allows you to connect your Victron products having VE.Direct connection to the device having RS232 port such as computer for monitoring and configuration. All you need to do is connect RS232 connector to your computer and VE.Direct connector to your Victron unit and you are ready to configure and monitor the unit.

$45.53

VE.Direct to BMV60xS Cable

VE.Direct to BMV60xS Cables are used to connect BMV-60xS to the Color Control GX for Battery monitoring. Victron Energy VE.Direct to BMV60xS Cable is available in two different sizes i.e. 1.5 m and 3 m.

$34.32$41.18

VE.Direct cable

A cable that is used to connect BMV-70x and low power MPPTs to the Color Control GX. Victron Energy VE.Direct Cable is available in different sizes including 0.3 m, 0.9 m, 1.8, 3 m, 5 m, and 10 m available in both straight and 90 degree angle models.

$23.22$36.26

VE.Direct non-inverting remote on-off cable

Use this cable to remotely control BlueSolar and SmartSolar MPPT charge controller models. However, it’s not necessary to use this cable on the larger SmartSolar models, as they feature an onboard Remote On/Off terminal. The charger will be enabled when the signal on the cable is high. The charger is disabled when the source signal is pulled low or left free floating.

$31.60

Non-inverting remote on-off cable

The cable translates the remote on/off driver logic from the VE.Bus BMS (normally high, and opencircuit in case of alarm) to the logic needed by above products, active pull down to switch off.

$31.60

Inverting remote on-off cable

The Inverting remote on-off cable is intended for products which require active pull down of the remote control terminal to switch on, while the source signal turns high when switch on is required.

Use this cable to connect the (discontinued) Phoenix Inverter 12/180, 24/180, 12/350 or 24/350 to a VE.Bus BMS or a BlueSolar MPPT Charger.

$31.60

RJ45-splitter 1xRJ45 male/15cm cable/2xRJ45 female

This splitter is used to connect the MultiPlus 500VA – 1600VA range in parallel and 3 phase configurations, or in other installations where multiple VE.Bus ports are required. It includes 1 x RJ45 male connector, 15cm long cable and 2 x RJ45 female connector.

$29.74

VE.Can to CAN-bus BMS

Use this cable to connect a CAN-bus enabled battery, not from Victron, to a Victron system. There are two types, A and B. See the manual for details on which cable to use for which brand of batteries.

$25.11

VE.Can RJ45 terminator

The VE.Can RJ45 terminator comes in a bag of two when ordered separately. The terminators are also included with some products, for example with the CANUSB. These are required for VE.Can networks. They are supplied with the Color GX.

$15.78

VE. Net to VE. Bus Converter

The purpose of the VVC is to combine the powerful control of the VE Configure software, with the simple interface of the VE.Net Panel. With the VVC, you can configure the advanced features, and view status information of your VE.Bus device from a VE.Net Panel.