Connection to the battery
The inverters are equipped with two DC connection cables with a length of 1.5 meters. If it is unavoidable to extend these cables, use a wire gauge of at least 2 times larger than the ones supplied with the inverter. Maximum recommended battery wire length is 5 meters.
The inverters are fitted with an internal DC fuse (see technical data). If the DC cable length is increased to more than 1.5 m, an additional fuse or DC circuit breaker must be inserted close to the battery.
Connecting the load
Some loads like motors or pumps draw large inrush currents in a start-up situation. In such circumstances, it is possible that the start-up current exceeds the over current trip level of the inverter. In this case the output voltage will quickly decrease to limit the output current of the inverter. If the over current trip level is continuously exceeded, the inverter will shut down and restart. If an overload occurs 3 times within 30 seconds the inverter will shut down. To restart the inverter: switch the Inverter “off”, wait 2 seconds and switch the Inverter “on”.
Never connect the output of the inverter to another AC source, such as a household AC wall outlet or a generator.